Two therapies.
 One circuit.
 Zero compromise.

Two therapies.
 One circuit.
 Zero compromise.


The AirSpiral™ 2-in-1 circuit allows you to seamlessly switch between NIV and NHF while delivering clinically required levels of humidity with less condensate.* 

 

* Compared with F&P RT219 and RT319 heated conventional circuits during internal testing.



Learn more about

NHF & NIV together

F&P Interfaces

Optimal Humidity


 

Less Condensate 

AirSpiral 2-in-1 technology produces up to 80% less condensate and 20% more humidity.*

Patient Comfort 

Small and light.

Its smoothbore internal walls enable the design of a smaller diameter tubing and reduces resistance to flow during NIV.*


The circuit clip holds the weight of the tube and allows it to be positioned to meet the needs of patient and clinician. This feature adds stability to the interface and reduces the chances of it pulling off the face.

 

AirSpiral 2-in-1

2 Min 57 Sec


Find out more about AirSpiral 2-in-1's features.

Therapy Flexibility for NHF and NIV
 

No matter how you want to use NHF and NIV,  AirSpiral 2-in-1 give you ease of use because you don't need to change circuits.

Compatible with F&P interfaces, including:

F&P Optiflow™ 3S

NHF INTERFACE

F&P Nivairo™ NIV

FULL FACE MASK

F&P Visairo™ NIV

UNDER NOSE MASK

F&P Optiflow+

NHF INTERFACE

 

 

To be used with the F&P MR850 Humidifier

AirSpiral 2-in-1 Instructional Videos


Circuit and Interface Setup 

AirSpiral Circuit Set up

NIV and NHF Interface Set up

Transitions between NIV/NHF

Transitions between vented NIV mask and NHF Interface

Transitions between non-vented NIV mask and NHF Interface

Why delivery of Optimal Humidity is important for NHF

Optimal Humidity is the condition in which airways naturally heat and humidify inspired gas - normally reaching 37ºC and 44 mg/L H2O (body temperature and pressure, saturated or BTPS).

Heated humidified gases are integral to enabling the high flow rates for nasal high flow (NHF) therapy. A dew-point setting of 37ºC is considered the standard setting for NHF (as evidenced by clinical research1,2).

The humidification levels assist in the comfortable delivery of NHF therapy and help to emulate the natural balance of heat and humidity in the respiratory system, as well as to support mucocilliary clearance.

The AirSpiral 2-in-1 has been designed to deliver the clinically required level of humidity so your patients can experience these benefits.

Learn More

Product Codes

Part No.DescriptionQuantity
850A61F&P 850 AirSpiral Adult NIV and NHF circuit kit10/box