Invasive ventilation breathing circuits

Fisher & Paykel Healthcare produces circuits designed to deliver heated and humidified gases to neonates during invasive ventilation.


View: product codes, support resources

Evaqua™ 2 technology

The circuits incorporate Evaqua 2 technology, which eliminates the need for water traps by enabling excess humidity to diffuse through the circuit wall before it condenses. The Evaqua 2 expiratory tube of the breathing circuit is made from a material containing millions of permeable cells.

 

Water vapor diffuses through the permeable membrane to the outside of the tube. As there is less condensate collecting in the tube, circuit breaks can be minimized and the breathing circuit can remain a closed system. The Evaqua 2 tube wall is made up of many layers, making it robust and resistant to kinking and damage.  

With conventional water-trap circuits, condensate can form in the expiratory limb where humidity in the gas flow touches cooler surfaces along the gas path. Evaqua 2 technology allows water vapor to diffuse through the expiratory limb wall before it has an opportunity to condense into liquid water within the circuit limb or the ventilator (neonatal ventilator or ventilator with neonatal modes).
Fig 1. Evaqua 2 compared with a conventional respiratory circuit
 

Compatible humidification systems


Reliable. Adaptable. Robust.

The F&P 850™ System delivers heated, humidified support across the neonatal respiratory care continuum.


Redefining expectations.

Precious new life deserves the best start possible, and the premium F&P 950™ humidification system contains the technology to help achieve this.

 

Product codes

  

Product codeDescriptionQuantity

F&P 850 Invasive Circuits

RT265Dual Heated Infant Circuit Kit with Evaqua 2 Technology and MR290 Autofeed Chamber (Flow > 4 L/min)10/box
RT266 Dual Heated Infant Circuit Kit with Evaqua 2 Technology and MR290 Autofeed Chamber (Flow 0.3 to 4 L/min) 10/box 
RT267 Dual Heated Infant Circuit Kit with Evaqua 2 Technology and MR290 Autofeed Chamber for SLE2000 Ventilators 10/box 
RT268 Dual Heated Infant Circuit Kit with Evaqua 2 Technology and MR290 Autofeed Chamber for SLE5000 Series Ventilators 10/box 
RT269 Dual Heated Infant Circuit Kit with Evaqua 2 Technology and MR290 Autofeed Chamber for SLE6000 Series Ventilators 10/box 
RT225 Dual Limb Infant Breathing Circuit Kit with Expiratory Water-trap and MR290 Autofeed Chamber (Flow > 4 L/min) 10/box 
RT226Dual Limb Infant Breathing Circuit Kit with Expiratory Water-trap and MR290 Autofeed Chamber (Flow 0.3 - 4 L/min) 10/box 
RT227Dual Limb Infant Breathing Circuit Kit with Expiratory Water-trap and MR290 Autofeed Chamber for SLE2000 Series Ventilators 10/box 
RT228Dual Limb Infant Breathing Circuit Kit with Expiratory Water-trap and MR290 Autofeed Chamber for SLE5000 Series Ventilators10/box 
F&P 950 Invasive Circuits
950N80 (J)Neonatal ventilator dual heated circuit kit10/box
950N81 (J)Neonatal ventilator dual heated circuit kit (with accessories)10/box
950N82 (J)SLE ventilator circuit kit10/box
J model available in North America only.
Support resources

Evaqua 2 Infant Circuit RT265 Specification Sheet

(PDF 0.1 MB)

Download

F&P 950™ Neonatal Ventilator Dual Heated Circuit Kit (with accessories)

(PDF 2.3 MB)

Download

F&P 950™ Neonatal Ventilator Dual Heated Circuit Kit J Model

(PDF 2.5 MB)

Download

Infant Circuit Water Trap RT225 Specification Sheet

(PDF 0.1 MB)

Download

Infant Circuit Water Trap RT226 Specification Sheet

(PDF 1.5 MB)

Download

Neonatal Ventilator Dual Heated Circuit Kit

(PDF 3.0 MB)

Download

Neonatal Ventilator Dual Heated Circuit Kit (with accessories) J Model

(PDF 2.5 MB)

Download

RT225 & RT226 User Instructions

(PDF 4.1 MB)

Download

RT265 & RT266 User Instructions

(PDF 4.1 MB)

Download

This product is not available for purchase by the general public. Always follow the directions for use.
 
F&P, Evaqua, F&P 850 and F&P 950 are trademarks of Fisher & Paykel Healthcare Limited. For patent information, see https://www.fphcare.com/ip