T-piece circuits

Fisher & Paykel Healthcare has three types of T-piece circuits: classic, ergonomic and humidified.


View: product codes, support resources

Our classic, ergonomic and humidified T-piece circuits can be connected to a mask or endotracheal tube and they all feature positive end-expiratory pressure (PEEP) valves for adjusting pressure.

Classic T-piece circuit

The classic T-piece circuit has a standard T-piece to connect to a mask or endotracheal tube along with a PEEP valve to adjust pressure.


 

Ergonomic T-piece circuit

In addition to the classic T-piece features, the ergonomic T-piece circuit includes a duckbill port for suctioning and delivering surfactant during resuscitation.

This T-piece circuit also has a blue protective cover that can be used to set and check pressure. The angled orientation of the PEEP valve has been designed to allow operators to use a more ergonomic hand position.


 

Humidified T-piece circuit

F&P Healthcare’s humidified T-piece circuit, incorporating a spiral heater-wire throughout the circuit tubing, is designed to deliver warm, humidified gas using the F&P MR850 heated humidifier and the MR290 auto-fill humidification chamber.

Resuscitation with heated and humidified gas is associated with a higher rate of normothermia (rectal temperature between 36.5 °C and 37.5 °C) on admission to the neonatal intensive care unit (NICU).1


 


F&P 850 System

Reliable. Adaptable. Robust.

The F&P 850™ System delivers heated, humidified support across the neonatal respiratory care continuum.
 
View F&P 850 System

Product codes

 

  
Product codeDescriptionQuantity
900RD010Single-use classic T-piece circuit*10/box
RD1300-10Single-use ergonomic T-piece circuit*10/box
900RD110Single-use humidified T-piece circuit**10/box

Suitable for use with the:
 * Neopuff™ T-piece resuscitator
 ** Neopuff T-piece resuscitator and the F&P 850 System (when delivering humidified resuscitation)

Support resources

Neopuff Classic T-Piece Specification Sheet (900RD010)

(PDF 1.2 MB)

Download

Neopuff Classic T-Piece User Instructions (900RD010)

(PDF 2.7 MB)

Download

Neopuff Humidified Setup Swing Tag

(PDF 4.5 MB)

Download

Neopuff Humidified T-Piece Circuit Specification Sheet (900RD110)

(PDF 1.0 MB)

Download

Neopuff Humidified T-Piece Circuit User Instructions (900RD110)

(PDF 3.1 MB)

Download

Neopuff RD900 Specification Sheet

(PDF 0.7 MB)

Download

Neopuff RD900 Technical Manual

(PDF 2.0 MB)

Download

Neopuff RD900 User Instructions

(PDF 4.8 MB)

Download
  1. Meyer MP, Owen LS and Te Pas AB. Use of heated humidified gases for early stabilization of preterm infants: A meta-analysis. Front. Pediatr 6, 2018, Oct 25. 319. View abstract

Product Codes

Part No. Description Quantity
RD1300-10 Single use Ergonomic T-piece circuit 10/box
900RD010 Single Use Classic T-Piece Circuit  10/box
900RD110 Single Use Humidified T-Piece Circuit 10/box

 

Resource download list

Neopuff Classic T-Piece Specification Sheet (900RD010)

(PDF 1.2 MB)

Download

Neopuff Classic T-Piece User Instructions (900RD010)

(PDF 2.7 MB)

Download

Neopuff Humidified Setup Swing Tag

(PDF 4.5 MB)

Download

Neopuff Humidified T-Piece Circuit Specification Sheet (900RD110)

(PDF 1.0 MB)

Download

Neopuff Humidified T-Piece Circuit User Instructions (900RD110)

(PDF 3.1 MB)

Download

Neopuff RD900 Specification Sheet

(PDF 0.7 MB)

Download

Neopuff RD900 Technical Manual

(PDF 2.0 MB)

Download

Neopuff RD900 User Instructions

(PDF 4.8 MB)

Download