Features and Benefits

Enhanced usability. Minimized condensation. Advanced protection.
 

Contact your F&P 950 representative

F&P 950 System Premium System Performance mantra. Easy to set up and use. Advanced Protection. Minimal condensation.

 

Advanced technology that pushes back on the challenges you face
We designed the F&P 950™ System to resolve many of the pain points you may have experienced when administering care with your present device. How many of these pain points are you familiar with? Circuit condensate, damaged or lost probes, complex setup, unclear alarm display, and limited temperature adjustability. 

5 icons depicting common challenges. Circuit condensate. Damaged or lost probes. Complex to set up. Unclear alarm display. Limited temperature adjustability.

Easy to set up and use

Close up of AirSpiral™ circuit showing integrated temperature probe.

Integrated probes

Temperature and flow probes have been integrated into the inspiratory limb and sensor cartridge, contributing to easier setup of the F&P 950 System. The integrated patient-end temperature sensor is disposed of with the single-use circuit, eliminating the need for disinfection or sterilization.
Close up of a person’s hand operating the F&P 950 System touch screen.

Interactive touch screen

With an adult circuit connected, an interactive touch screen offers selection of Invasive, Mask, and Optiflow™ modes via a drop-down menu. While operating in either Mask or Optiflow mode, the temperature can be adjusted to support patient comfort. 


Close up of a person’s hand connecting F&P 950 circuit to device.

Fewer assembly connections*

The number of connections is limited to enable easy assembly and decrease the potential for system alarms due to incorrect setup.

*As compared to the F&P 850 System



Minimal condensation

Close-up of hand holding Thermadapt technology and Evaqua 2 neonatal expiratory limb.

Thermadapt technology

The 1.75-meter-long neonatal inspiratory limb incorporates Thermadapt™ technology which eliminates the need for an unheated extension. Different heating zones enable the breathing circuit to automatically adapt to changing ambient environments, such as those found in incubators and infant warmers. 

Close up cut out showing AirSpiral™ circuit technology

AirSpiral inspiratory

AirSpiral™ technology protects humidified gases from the ambient conditions using insulating pockets of air and integrated wall heating along the length of the inspiratory limb. Compared with a conventional inspiratory limb, this technology helps to reduce the formation of condensate, while the smoothbore internal walls improve resistance to flow.
Close up cut out of Evaqua 2 Expiratory circuit technology showing semi-permeable membrane.

Evaqua 2 expiratory

Evaqua™ technology minimizes condensate by allowing humidity to freely permeate through the wall of the expiratory limb while preventing the diffusion of pathogens. Compared with a conventional expiratory limb, this technology decreases condensate in the expiratory filter and helps to reduce ventilation issues caused by mobile condensate.


Advanced protection

Close up of SensiDomes covering temperature and flow probes

SensiDomes

SensiDomes™ are silicone covers that stretch over the temperature and flow probes attached to the sensor cartridge and are embedded within the wall of the humidification chamber. These provide a microbial barrier between the probes and the humidified gases, while allowing accurate measurement to occur. The probes are not exposed to humidified gases so disinfection or sterilization is not required.

Close up of F&P 950 System screen showing disconnection alarm animation

Intuitive alarms

Animations or text are displayed on the touch screen when the device enters an alarm state, clearly communicating the corrective action required to troubleshoot the device.

Plus...
Circuit type detection Icon. Close-up of the F&P 950 circuit connection with AirSpiral technology

Circuit Type Detection
Incorrect Set-up Alarms Icon. Close-up of ringing bell with exclamation mark

Incorrect Set-up Alarms
USB Software Upgrades Icon. Close-up of hard drive with USB symbol and upload arrow

USB Software Upgrades
Customizable defaults icon. Close up of 3 knobs being moved, depicting customization

Customizable Defaults
USB Downloadable logs Icon. Close-up of folder with USB symbol and download arrow

USB Downloadable Logs
Incoming Gas Sensor Icon. Close up of gust of air blowing at F&P 950 System flow probe

Incoming Gas Sensor

Using the F&P 950 System has flow-on outcomes in several areas

 


Patient care

Hospital

Caregiving

 


If you’re interested in learning more about these outcomes, or would like to evaluate the F&P 950 System, please complete the form below.

Contact your F&P 950 representative
If you have an enquiry about our products, please provide the following information so a Fisher & Paykel Healthcare representative can contact you. For further details on how this information will be used, see below or go to our privacy statement.


I consent to Fisher & Paykel Healthcare keeping me informed about new F&P products, clinical updates, events and promotions on the following topics:



CAPTCHA