Invasive ventilation breathing circuits

Fisher & Paykel Healthcare produces circuits designed to deliver heated and humidified gases to pediatric patients during invasive ventilation.


View: product codes, support resources

Evaqua™ 2 technology

The circuits incorporate Evaqua 2 technology, which eliminates the need for water traps by enabling excess humidity to diffuse through the circuit wall before it condenses. The Evaqua 2 expiratory tube of the breathing circuit is made from a material containing millions of permeable cells.

 

Water vapor diffuses through the permeable membrane to the outside of the tube. As there is less condensate collecting in the tube, circuit breaks can be minimized and the breathing circuit can remain a closed system. The Evaqua 2 tube wall is made up of many layers, making it robust and resistant to kinking and damage.  

With conventional water-trap circuits, condensate can form in the expiratory limb where humidity in the gas flow touches cooler surfaces along the gas path. Evaqua 2 technology allows water vapor to diffuse through the expiratory limb wall before it has an opportunity to condense into liquid water within the circuit limb or the ventilator (neonatal ventilator or ventilator with pediatric modes).

Fig 1. Evaqua 2 compared with a conventional respiratory circuit

 



Circuit changeover


Fisher & Paykel Healthcare’s circuit range comprises adult, pediatric and neonatal circuits.
 
For a pediatric application using F&P 850™ circuits, the recommended point to change from an infant circuit to an adult circuit is 12 to 15 kg or 120 ml tidal volume (VT), depending on your ventilation strategy.



Fig 2. The recommended point for a circuit changeover is 12 to 15 kg or 120 ml tidal volume (VT).

 

Compatible humidification systems


Reliable. Adaptable. Robust.

The F&P 850™ System delivers heated, humidified support across the pediatric respiratory care continuum.


Redefining expectations.

The F&P 950™ is a premium-performance humidification system designed to be easy to set up and use, minimize condensate, and provide advanced protection.

 

Product codes

 

  
Product codeDescriptionQuantity

F&P 850 invasive circuits

  
RT265Dual heated infant circuit kit with Evaqua 2 technology and MR290 autofeed chamber (flow > 4 L/min)10/box
RT266Dual heated infant circuit kit with Evaqua 2 technology and MR290 autofeed chamber (flow 0.3 to 4 L/min)10/box
RT267Dual heated infant circuit kit with Evaqua 2 technology and MR290 autofeed chamber for SLE2000 ventilators10/box
RT268Dual heated infant circuit kit with Evaqua 2 technology and MR290 autofeed chamber for SLE5000 series ventilators10/box
RT269Dual heated infant circuit kit with Evaqua 2 technology and MR290 autofeed chamber for SLE6000 series ventilators10/box
RT225Dual limb infant breathing circuit kit with expiratory water-trap and MR290 autofeed chamber (flow > 4 L/min)10/box
RT226Dual limb infant breathing circuit kit with expiratory water-trap and MR290 autofeed chamber (flow 0.3 – 4 L/min)10/box
RT227Dual limb infant breathing circuit kit with expiratory water-trap and MR290 autofeed chamber for SLE2000 series ventilators10/box
RT228Dual limb infant breathing circuit kit with expiratory water-trap and MR290 autofeed chamber for SLE5000 series ventilators10/box
F&P 950 invasive circuits
  
950P81 (J)*Pediatric ventilator dual heated circuit kit10/box
950N80 (J)*Neonatal ventilator dual heated circuit kit10/box
950N81 (J)*Neonatal ventilator dual heated circuit kit (with accessories)10/box
950N82 (J)*SLE ventilator circuit kit10/box

*J model available in North America only.

 

Support resources

Evaqua 2 Infant Circuit RT265 Specification Sheet

(PDF 0.1 MB)

Download

Evaqua 2 Infant Circuit RT268 Specification Sheet

(PDF 0.1 MB)

Download

Evaqua 2 Infant Circuit RT269 Specification Sheet

(PDF 0.8 MB)

Download

F&P 950™ Neonatal Ventilator Dual Heated Circuit Kit (with accessories)

(PDF 2.3 MB)

Download

F&P 950™ Neonatal Ventilator Dual Heated Circuit Kit J Model

(PDF 2.5 MB)

Download

F&P 950™ Pediatric Ventilator Dual Heated Circuit Kit (with pressure line)

(PDF 2.3 MB)

Download

F&P 950™ Pediatric Ventilator Dual Heated Circuit Kit (with pressure line) J Model

(PDF 2.7 MB)

Download

F&P 950™ SLE Ventilator Circuit Kit J Model

(PDF 1.4 MB)

Download

Infant Circuit Water Trap RT225 Specification Sheet

(PDF 0.1 MB)

Download

Infant Circuit Water Trap RT226 Specification Sheet

(PDF 1.5 MB)

Download

Infant Circuit Water Trap RT227 Specification Sheet

(PDF 1.0 MB)

Download

Infant Circuit Water Trap RT228 Specification Sheet

(PDF 1.0 MB)

Download

Neonatal Ventilator Dual Heated Circuit Kit (with accessories) J Model

(PDF 2.5 MB)

Download

RT225 & RT226 User Instructions

(PDF 4.1 MB)

Download

RT227 & RT228 User Instructions

(PDF 4.1 MB)

Download

RT265 & RT266 User Instructions

(PDF 4.1 MB)

Download

RT269 User Instructions

(PDF 3.7 MB)

Download

This product is not available for purchase by the general public. Always follow the directions for use.

F&P, Evaqua, F&P 850 and F&P 950 are trademarks of Fisher & Paykel Healthcare Limited. For patent information, see www.fphcare.com/ip